A device used to open and close an electric circuit. It is also called a switch. It generally consists of a movable contact and a fixed contact, and an electric circuit is formed (closed) when the movable contact is moved and its contact surface comes into contact with the contact surface of the fixed contact. The opposite operation separates the contact surfaces and opens the electric circuit. During this opening and closing operation, the contacts are designed to maintain their open or closed state, and are designed to maintain that state even if they are subjected to some vibration. In terms of the current interruption capacity when opening a switch, a 100-200 volt switch can interrupt the current during normal use (load current), but cannot interrupt large currents such as fault currents, and even higher voltage switches cannot interrupt current even with normal load currents. For this reason, some switches are equipped with an arc quenching device that can interrupt currents up to the load current. These are called load switches or load circuit breakers. Switches that can interrupt large currents are called circuit breakers and are distinguished from switches. Because the current passing through the switch passes through the contact surface, the temperature rises due to the contact surface resistance. To suppress this temperature rise and allow as large a current as possible to pass with the same shape, the contacts are made of a material with low electrical resistance, while measures are taken to reduce contact resistance, such as increasing the contact pressure and increasing the contact area. The contacts are generally made of copper, with silver being used for particularly large currents. Sintered alloys of silver-tungsten and copper-tungsten are used to withstand wear caused by arcs. Those that open and close one electric wire are called single pole or single pole, those for two wires are called double pole, and those for three wires are called triple pole. Those that only open and close are called single throw, and those for switching are called double throw. The movable contact can be operated manually, electromagnetically, compressed air, hydraulically, etc. Non-manual types are electrically operated and can also be operated remotely. [Masami Okamura and Yoshifumi Oura] kindsThere are many types available depending on the voltage, current, purpose, etc. used. Switches used in low-voltage circuits(1) Indoor switches: These are used in conjunction with lights and electrical appliances in general buildings such as homes and offices, and include tap-type switches, pull switches, and push button switches. Depending on where they are installed, there are recessed switches that are inserted into the wall, exposed switches that are attached to the wall or board, canopy switches that are located inside the light fixture and operated with a cord, and intermediate switches that are placed in the middle of the cord. All of these have a small current capacity of less than a few amperes. No-fuse breakers are used at electrical inlets in ordinary homes. (2) Electromagnetic contactor: A device that opens and closes using electromagnetic force and is mainly used to open and close motors. (3) Knife switch: Widely used as a main switch for electric lighting and power wiring, a hand switch for operating motors, etc. Three-pole types are used for three-phase or single-phase three-wire systems. Two-pole types are used for single-phase two-wire systems. As they do not have the ability to interrupt short-circuit current, many are equipped with fuses. However, when using a three-pole switch in a single-phase three-wire circuit, a fuse must not be inserted in the neutral wire. This is because if the neutral wire is broken, the voltage on the load side will become unbalanced. (4) Other switches include microswitches for small currents, vacuum switches where the opening and closing part is made into a vacuum, non-contact switches which have no moving parts and use a coil containing an iron core to utilize the significant difference in impedance when the iron core is saturated and unsaturated, and mercury switches which have mercury placed in the opening and closing part and can be opened and closed by moving the position of the mercury ( ).[Masami Okamura and Yoshifumi Oura] Switches used in circuits with high voltage or higher(1) Circuit breaker: Used over a wide voltage range from 3,000 to 500,000 volts. (2) Pole-mounted switches These are mounted on poles for 6,000-volt distribution lines. When a fault occurs in the distribution line, this switch is opened to isolate the faulty section and transmit power to the healthy section. Because of this method of use, they are also called sectional switches. Structurally, there are various types, such as vacuum switches, which use a vacuum valve as the contactor placed inside an iron box, and air switches, which open and close with a contactor placed in the air. The open/close state of the contactor of a vacuum switch cannot be directly observed with the naked eye, but the open/close state of an air switch can be observed directly with the naked eye, making it easy to check the state. Pole switches are so named because they are often attached to the cross arm of a utility pole, but for underground distribution lines they are installed inside the distribution tower. In either case, most are manually operated, but there are also electromagnetically operated types. (3) Automatic sectionalizing switch: A type of electromagnetic pole-mounted switch that is installed at key locations on a distribution line. When a fault occurs in a distribution line, the switch automatically selects and isolates the faulty section and continues transmitting power, and switches to another distribution line to transmit power to the healthy section that is experiencing a power outage. [Masami Okamura and Yoshifumi Oura] Control SwitchA switch used to remotely control circuit breakers, switches, motors, etc. Mostly drum type switches are used, but pull button type switches are also used. [Masami Okamura and Yoshifumi Oura] [Reference items] | | | | | |©Takashi Aoki Main types of switches (for low-voltage circuits) [Figure... Source: Shogakukan Encyclopedia Nipponica About Encyclopedia Nipponica Information | Legend |
電路の開閉に使用される器具。開閉器ともいう。一般的な構造は可動接触部と固定接触部から構成され、可動接触子を動かしてその接触面が固定接触子の接触面に接触することにより電路が形成される(閉の状態となる)。また、反対の操作により接触面が離れて電路が開の状態となる。この開閉操作の際、接触子は開または閉の状態を保持できる構造となっており、多少の振動が与えられてもその状態を保持するようにつくられている。また、開閉器の開操作の際の電流遮断能力でみると、100~200ボルトスイッチでは、通常使用時の電流(負荷電流)は遮断できるが、故障電流のような大電流遮断はできないし、さらに高電圧開閉器では、通常の負荷電流でも電流遮断できない。このため、負荷電流程度の電流まで遮断できるアーク消滅装置を取り付けたスイッチもある。これらは負荷スイッチまたは負荷遮断器とよんでいる。また、大電流遮断のできるスイッチは、遮断器とよびスイッチと区別している。 スイッチを通る電流は接触面を通過するため、接触面抵抗により温度が上昇する。この温度上昇を抑え同一形状でもできるだけ大きな電流が流せるようにするため、接触子は電気抵抗の少ない材質のものを選ぶと同時に、接触圧力を高めたり、接触面積を広くとるなど、接触抵抗を小さくする対策がなされている。接触子の材質は一般には銅、とくに大きな電流用には銀が用いられる。また、アークによる消耗に耐えるものとしては、銀・タングステン、銅・タングステンの焼結合金が用いられる。 1本の電線を開閉するものを一極または単極、2本の電線用は二極、3本の電線用は三極とよび、開閉だけのものを単投、切り替え用を双投とよんでいる。可動接触子の操作は手動のほか、電磁力、圧縮空気、油圧などが使われる。手動以外のものは電気操作とし遠隔操作も可能である。 [岡村正巳・大浦好文] 種類使用する電圧、電流、目的などにより多くの種類がある。 低圧の回路に使われるスイッチ(1)屋内用スイッチ 住宅、事務所などの一般建物内で電灯や電気器具などに付随して用いられるもので、タンプラスイッチ、プルスイッチ、押しボタンスイッチなどがある。取付け場所別には、壁に入れる埋込みスイッチ、壁面や板面などに取り付ける露出スイッチ、電灯器具内にあって紐(ひも)で操作するカノピスイッチ、コードの中間に置く中間スイッチなどがある。いずれも電流容量が小さく、数アンペア以下である。 一般家庭の電気の引込み口にはノーヒューズブレーカーが使用される。 (2)電磁開閉器 電磁力の力で開閉を行うもので、おもにモーターの開閉に多く使用される。 (3)ナイフスイッチ 電灯や動力配線の主幹スイッチ、モーター操作用の手元スイッチなどに広く用いられる。三極形は、三相用または単相三線式用に使われる。単相二線式は二極のものを使用する。短絡電流を遮断する能力をもたないため、ヒューズ付きとするものが多い。ただし、単相三線式回路に三極スイッチを使用するときは、中性線にはヒューズを入れてはならない。中性線が断線すると負荷側の電圧がアンバランスになるからである。 (4)その他のスイッチ 小電流用のマイクロスイッチ、開閉部分を真空にした真空スイッチ、動作部分がなく鉄心入りのコイルを置いて鉄心部分の飽和・未飽和時のインピーダンスの著しい相違を利用した無接点スイッチ、開閉部分に水銀を置き水銀の位置の移動で開閉できる水銀スイッチなどがある( )。[岡村正巳・大浦好文] 高圧以上の回路に使われるスイッチ(1)断路器 3000~50万ボルトに至る広い電圧の範囲で使用される。 (2)柱上スイッチ 6000ボルトの配電線の柱上に取り付けられる。配電線が故障したとき、このスイッチを開放して故障区間を切り離し、健全部分に送電する。このような使い方をするため区分スイッチともよばれる。構造的には、鉄箱内に接触子を置き、接触子に真空バルブを使う真空スイッチとよばれるもの、気中に置かれた接触子で開閉する気中スイッチなどの種類がある。真空スイッチは接触子の開閉状態が直接目視できないが、気中スイッチは直接目視でき、状態確認が容易である。 柱上スイッチは電柱の腕金に取り付けられる場合が多いためにこのようによばれるが、地中配電線では配電塔の中に設置される。いずれの場合も手動操作形が多いが、電磁操作のものもある。 (3)自動区分スイッチ 電磁操作形の柱上スイッチの一種で、配電線の要所要所に設置されている。配電線に故障が発生したとき、故障区間を自動的に選別して切り離し、送電するとともに、健全区間で停電している区間には他の配電線に切り替え送電するスイッチである。 [岡村正巳・大浦好文] 制御スイッチ遠方から遮断器、スイッチ、モーターなどを制御するためのスイッチで、主としてドラム形スイッチが使用されるが、引きボタン形スイッチも用いられる。 [岡村正巳・大浦好文] [参照項目] | | | | | |©青木 隆"> スイッチのおもな種類(低圧回路用)〔図… 出典 小学館 日本大百科全書(ニッポニカ)日本大百科全書(ニッポニカ)について 情報 | 凡例 |
>>: Disc-winged bat (English spelling)
…However, by skillfully arranging magnets with ma...
A merchant organization organized to manage trade...
…Rhymes are not unrelated to rhythm, since the fo...
...However, efforts to increase production while ...
A small tree of the Agavaceae family. Native to Me...
Cultural anthropologist. After the Second World W...
…He was born in Bombay, India, and studied in var...
…After Toshitsugu Tsuchiya became the magistrate ...
...A cylindrical machine called a shield (origina...
…The fur of newborn karakul lambs from the Astrak...
...the correct anatomical name is the pinna ('...
Olympic Council of Asia. Established in 1982 as a ...
The former name of the city of Heraklion in the c...
The predecessor of the Folk Culture Research Inst...
A general term for Mesolithic rock paintings found...